Come posso risolvere il mio array RAID?


8

Ho appena effettuato il check-in nel mio array RAID questa mattina e quello che ho ottenuto è:

$ cat /proc/mdstat
Personalities : [raid1] [linear] [multipath] [raid0] [raid6] [raid5] [raid4] [raid10] 
md1 : active raid1 sdc7[0]
      238340224 blocks [2/1] [U_]

md0 : active raid1 sdc6[0]
      244139648 blocks [2/1] [U_]

md127 : active raid1 sdc3[0]
      390628416 blocks [2/1] [U_]

unused devices: <none>
$

Il che, credo, significa che un disco dei miei array è morto, è vero?

Come posso fare per risolvere correttamente i problemi in futuro? Il mio /etc/mdadm/mdadm.confaspetto è:

$ cat /etc/mdadm/mdadm.conf
# mdadm.conf
#
# Please refer to mdadm.conf(5) for information about this file.
#

# by default (built-in), scan all partitions (/proc/partitions) and all
# containers for MD superblocks. alternatively, specify devices to scan, using
# wildcards if desired.
#DEVICE partitions containers

# auto-create devices with Debian standard permissions
CREATE owner=root group=disk mode=0660 auto=yes

# automatically tag new arrays as belonging to the local system
HOMEHOST <system>

# instruct the monitoring daemon where to send mail alerts
MAILADDR root

# definitions of existing MD arrays
ARRAY /dev/md127 UUID=124cd4a5:2965955f:cd707cc0:bc3f8165
ARRAY /dev/md0 UUID=91e560f1:4e51d8eb:cd707cc0:bc3f8165
ARRAY /dev/md1 UUID=0abe503f:401d8d09:cd707cc0:bc3f8165

Come faccio a sapere quale unità fisica è rotta e deve essere sostituita?

Grazie

EDIT1

# mdadm --detail /dev/md0
/dev/md0:
        Version : 0.90
  Creation Time : Tue Sep  1 19:15:33 2009
     Raid Level : raid1
     Array Size : 244139648 (232.83 GiB 250.00 GB)
  Used Dev Size : 244139648 (232.83 GiB 250.00 GB)
   Raid Devices : 2
  Total Devices : 1
Preferred Minor : 0
    Persistence : Superblock is persistent

    Update Time : Mon Sep 21 07:11:24 2015
          State : clean, degraded 
 Active Devices : 1
Working Devices : 1
 Failed Devices : 0
  Spare Devices : 0

           UUID : 91e560f1:4e51d8eb:cd707cc0:bc3f8165
         Events : 0.76017

    Number   Major   Minor   RaidDevice State
       0       8       38        0      active sync   /dev/sdc6
       1       0        0        1      removed
root@regDesktopHome:~# 

Perché direbbe Failed Devices : 0?

EDIT2
Aprendo Gparted, posso guardare entrambi, /dev/sdbe /dev/sdcquali erano i miei due RAIDdischi. Tuttavia, mdadm pensa che /dev.sdbsia stato rimosso per qualche motivo ... è strano. Ho provato a montare una partizione su `` / dev / sdb` e ho ottenuto quanto segue

$sudo mount /dev/sdb7 test
[sudo] password for ron: 
mount: unknown filesystem type 'linux_raid_member'

che sembra tutto cooretto. Come posso ripristinare il mio array RAID?

MODIFICA 3

Ho corso smartctl -a /dev/sdce smartctl -a /dev/sdb, l'ho fatto anche badblocks /dev/sdce badblocks /dev/sdbe mentre sdcsembra pulito al 100% , ho sdbrestituito alcuni blocchi danneggiati:

# badblocks /dev/sdb
16130668
16130669
16130670
16130671

Sarebbe potenzialmente la causa dell'errore che sto vedendo? Qualche modo per riparare / ignorare questi blocchi danneggiati o devo sostituire invece l'unità?

MODIFICA 4

# smartctl --all /dev/sdb
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-62-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.12
Device Model:     ST31000528AS
Serial Number:    6VP0308B
LU WWN Device Id: 5 000c50 013d3ae45
Firmware Version: CC34
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Sat Sep 26 11:35:02 2015 PDT

==> WARNING: A firmware update for this drive may be available,
see the following Seagate web pages:
http://knowledge.seagate.com/articles/en_US/FAQ/207931en
http://knowledge.seagate.com/articles/en_US/FAQ/213891en

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  600) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 195) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103f) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   114   099   006    Pre-fail  Always       -       78420742
  3 Spin_Up_Time            0x0003   095   095   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   099   099   020    Old_age   Always       -       1240
  5 Reallocated_Sector_Ct   0x0033   099   099   036    Pre-fail  Always       -       60
  7 Seek_Error_Rate         0x000f   082   060   030    Pre-fail  Always       -       199357441
  9 Power_On_Hours          0x0032   052   052   000    Old_age   Always       -       42401
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   099   037   020    Old_age   Always       -       1240
183 Runtime_Bad_Block       0x0000   098   098   000    Old_age   Offline      -       2
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   094   094   000    Old_age   Always       -       6
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       0
189 High_Fly_Writes         0x003a   050   050   000    Old_age   Always       -       50
190 Airflow_Temperature_Cel 0x0022   062   046   045    Old_age   Always       -       38 (Min/Max 30/38)
194 Temperature_Celsius     0x0022   038   054   000    Old_age   Always       -       38 (0 17 0 0 0)
195 Hardware_ECC_Recovered  0x001a   030   012   000    Old_age   Always       -       78420742
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       1
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       1
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       73332271657814
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       2822963046
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       2361465529

SMART Error Log Version: 1
ATA Error Count: 6 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 6 occurred at disk power-on lifetime: 42372 hours (1765 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 d9 44 ec 01  Error: UNC at LBA = 0x01ec44d9 = 32261337

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 d8 44 ec 41 00      09:26:28.967  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      09:26:28.941  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 a0 00      09:26:28.940  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      09:26:28.928  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      09:26:28.901  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]

Error 5 occurred at disk power-on lifetime: 42372 hours (1765 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 d9 44 ec 01  Error: UNC at LBA = 0x01ec44d9 = 32261337

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 d8 44 ec 41 00      09:26:26.095  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      09:26:26.069  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 a0 00      09:26:26.068  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      09:26:26.055  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      09:26:26.029  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]

Error 4 occurred at disk power-on lifetime: 42372 hours (1765 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 d9 44 ec 01  Error: UNC at LBA = 0x01ec44d9 = 32261337

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 d8 44 ec 41 00      09:26:23.222  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      09:26:23.195  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 a0 00      09:26:23.194  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      09:26:23.182  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      09:26:23.137  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]

Error 3 occurred at disk power-on lifetime: 42372 hours (1765 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 d9 44 ec 01  Error: UNC at LBA = 0x01ec44d9 = 32261337

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 d8 44 ec 41 00      09:26:20.351  READ FPDMA QUEUED
  60 00 80 e8 44 ec 41 00      09:26:20.350  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      09:26:20.324  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 a0 00      09:26:20.323  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      09:26:20.311  SET FEATURES [Set transfer mode]

Error 2 occurred at disk power-on lifetime: 42372 hours (1765 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 d9 44 ec 01  Error: UNC at LBA = 0x01ec44d9 = 32261337

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 80 e8 44 ec 41 00      09:26:17.478  READ FPDMA QUEUED
  60 00 40 a8 44 ec 41 00      09:26:17.478  READ FPDMA QUEUED
  60 00 20 88 44 ec 41 00      09:26:17.476  READ FPDMA QUEUED
  60 00 08 80 44 ec 41 00      09:26:17.453  READ FPDMA QUEUED
  27 00 00 00 00 00 e0 00      09:26:17.427  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

# 

MODIFICA 5

Mi sono reso conto che dopo aver scollegato /dev/sdb, il precedente /dev/sdcè ora /dev/sdb. Ho confermato smartctl -a /dev/sdbche il numero seriale è cambiato dopo l'avvio con il disco danneggiato scollegato. Sono sfortunato e l'unità non è coperta da garanzia , quindi riceverò una nuova unità sostitutiva.


A proposito: dovresti vedere [UU] per un mirror sano, non [U_]. Come pensavi, significa che manca uno dei tuoi specchi. Il suggerimento di @ Halfgaar è il migliore.
Tim S.

Rielaborare 6, hai fatto mdadm --manage ... --add ...ciò che suggeriva Halfgaar?
MadHatter,

2
Una delle cose chiave sui siti di Stack Exchange è che non sono forum e non ci sono discussioni. Hai fatto una domanda, è stata data una risposta. Se hai più domande (correlate), dovresti farle come nuove domande e, se applicabile, fare riferimento all'originale. Prima di farlo, potresti voler cercare nel sito.
user9517

Risposte:


11

Visto che non vedi l'unità guasta (contrassegnata con F) nell'output di cat /proc/mdstat, hai avviato il server da quando l'array è stato degradato.

Puoi ottenere informazioni con mdadm --detail /dev/md0. Questo probabilmente ti dirà quale altra unità dovrebbe essere presente.

Per rispondere alla tua modifica:

/dev/sdbPrima analizzerei . Utilizzare smartctl -aper verificare (soprattutto) il conteggio dei settori riallocato e il registro degli errori. Fai un autotest con smartctl -t long /dev/sdb. Usa badblocks, ecc.

Poi:

  • Se si sostituisce /dev/sdb, copiare la tabella delle partizioni da /dev/sdc. Se non sono GPT, puoi usare sfdisk -d /dev/sdc | sfdisk /dev/sdb. Oppure, se sono GPT, è possibile utilizzare gdiskper salvare la tabella delle partizioni in un file, quindi caricarla. È nascosto sotto funzioni avanzate.
  • Qualcosa di generale da considerare: se il tuo (nuovo) disco ha settori 4K, assicurati che le partizioni siano allineate a 4K .
  • Se desideri aggiungere nuovamente quelli esistenti /dev/sdb, potresti voler eseguire mdadm --zero-superblocktutte le partizioni esistenti.
  • Quindi puoi mdadm --manage /dev/md0 --add /dev/sdb6e lo stesso per md1esdb7

Inutile dire che alcuni comandi cancellano i tuoi dati se mescoli le tue unità. Quindi, assicurati di cos'è sdce sdb...

Modifica: su blocchi danneggiati: se uno strumento a livello di software rileva blocchi danneggiati, l'unità viene arrestata. Normalmente, i dischi li nascondono riallocandoli in modo trasparente al momento della scrittura. Google per "riallocazione del settore del disco rigido". L' smartctl -aoutput dovrebbe mostrare settori riallocati per sdb. Quindi sì, il tuo sdbè stato espulso dall'array e devi sostituirlo.

Modifica: smartctl -asull'output. Ci sono due cose che sono di primaria importanza:

  • Mostra 60 settori riallocati. Anche se il valore normalizzato è ancora 99 e sarebbe ufficialmente 'cattivo' solo se raggiungesse 36 (conta alla rovescia), non dovresti fidarti dei dischi che iniziano a riallocare i settori. Quindi, specialmente se questo valore inizia a cambiare, il valore grezzo è importante. Puoi persino configurare il smartdmonitoraggio per te.
  • Il registro degli errori mostra le voci all'età di 42372 ore. Si può dire che è stato di recente, a causa del parametro 9 (nel tuo caso), Power on hours. Ci sono cose innocue che possono causare voci di log degli errori SMART, come dare comandi ATA errati, ma in questo caso, poiché hai un array degradato, è probabile che siano correlate.

Per quanto riguarda determinare quale disco è nel tuo sistema; per esempio, fare dmesg |grep -i sdbsarà di aiuto. Probabilmente hai tre dischi nel tuo sistema ed sdbè quello sul tuo secondo controller SATA, che può essere chiamato 1 o 2, a seconda che sia basato su zero o su uno.

Poiché è probabile che sdatu sdbesegua l' avvio , puoi semplicemente sostituire ed eseguire le operazioni che ho descritto sopra. Se l'unità di avvio è rotta, speri di avere:

  • Grub installato anche su altri dischi.
  • Avere un server che può effettivamente avviarsi da un altro disco.

L'altro giorno con un server Dell, non voleva iniziare da sdbquando c'era un vuoto sda. Ci sono voluti alcuni convincenti e improvvisanti.

A volte è necessario tradurre nomi simili ata1.01a nomi di dispositivi reali. Ad esempio, i dischi difettosi daranno errori del kernel che dicono "eccezione ATA su ata1.01" o parole in tal senso. Leggi questa risposta per questo. (Ho configurato il nostro sistema di registrazione centrale per avvertirmi di quegli errori del kernel, perché sono un'indicazione affidabile del fallimento del disco in sospeso).


Anche aggiunto EDIT2 ora
stdcerr

1
@cerr Modifico la risposta spiegando come analizzare la situazione.
Halfgaar,

1
@cerr Ho commentato la tua scoperta di blocchi danneggiati.
Halfgaar,

1
@cerr ho modificato per dare un'idea smartctldell'output.
Halfgaar,

1
@cerr Questo è già nella mia risposta, a proposito del--add
Halfgaar
Utilizzando il nostro sito, riconosci di aver letto e compreso le nostre Informativa sui cookie e Informativa sulla privacy.
Licensed under cc by-sa 3.0 with attribution required.